Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
Arch Orthop Trauma Surg ; 144(4): 1603-1609, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38441618

RESUMO

INTRODUCTION: Distal radioulnar joint (DRUJ) instabilities are challenging and their optimal treatment is controversial. In special cases or when reconstruction of the stabilizing triangular fibrocartilage complex (TFCC) fails, K-wire transfixation can be performed. However, no consensus has been reached regarding the rotational position of the forearm in which this should be done. Therefore, it was investigated whether anatomical reduction would best be achieved by transfixation in neutral position or supination of the forearm. MATERIALS AND METHODS: Twelve cadaveric upper limbs were examined before dissection of the DRUJ stabilizing ligaments and after closed transfixation in both positions by C-arm cone-beam CT. Whether this was first done in neutral position or in supination was randomized. The change in the radioulnar ratio (RR) in percentage points (%points) was analyzed using Student's t-test. RR was used since it is a common and sensitive method to evaluate DRUJ reduction, expressing the ulnar head's position in the sigmoid notch as a length ratio. RESULTS: The analysis showed an increased change in RR in neutral position with 5.4 ± 9.7%points compared to fixation in supination with 0.2 ± 16.1%points, yet this was not statistically significant (p = 0.404). CONCLUSIONS: Neither position leads to a superior reduction in general. However, the result was slightly closer to the anatomical position in supination. Thus, transfixation of the DRUJ should be performed in the position in which reduction could best be achieved and based on these data, that tends to be in supination. Further studies are necessary to validate these findings and to identify influential factors.


Assuntos
Antebraço , Instabilidade Articular , Humanos , Supinação , Pronação , Fenômenos Biomecânicos , Articulação do Punho/cirurgia , Cadáver , Instabilidade Articular/cirurgia
2.
Int J Med Robot ; 20(1): e2607, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38536717

RESUMO

BACKGROUND: The aim of the study was to validate a software-based planning method for the Schoettle Point and to evaluate precision and time efficiency of its live overlay on the intraoperative X-ray. METHODS: A software-based method was compared with surgeons' manual planning in an inter- and intrarater study. Subsequently, K-wire placement was performed with and without an overlay of the planning. The time used and the precision achieved were statistically compared. RESULTS: The average deviation between the surgeons (1.68 mm; 2.26 mm) was greater than the discrepancy between the surgeons and the software-based planning (1.30 mm; 1.38 mm). In the intrarater comparison, software-based planning provided consistent results. Live overlay showed a significantly lower positioning error (0.9 ± 0.5 mm) compared with that without overlay (3.0 ± 1.4 mm, p = 0.000; 3.1 ± 1.4 mm, p = 0.001). Live overlay did not achieve a significant time gain (p = 0.393; p = 0.678). CONCLUSION: The software-based planning and live overlay of the Schoettle Point improves surgical precision without negatively affecting time efficiency.


Assuntos
Instabilidade Articular , Luxação Patelar , Procedimentos de Cirurgia Plástica , Humanos , Luxação Patelar/diagnóstico por imagem , Luxação Patelar/cirurgia , Articulação do Joelho/cirurgia , Ligamentos Articulares , Radiografia , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/cirurgia
3.
J Orthop Surg Res ; 18(1): 924, 2023 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-38044441

RESUMO

BACKGROUND: Intraoperative 3D imaging using cone-beam CT (CBCT) provides improved assessment of implant position and reduction in spine surgery, is used for navigated surgical techniques, and therefore leads to improved quality of care. However, in some cases the image quality is not sufficient to correctly assess pedicle screw position and reduction, especially due to metal artifacts. The aim of this study was to investigate whether changing the acquisition trajectory of the CBCT in relation to the pedicle screw position during dorsal instrumentation of the spine can reduce metal artifacts and consequently improve image quality as well as clinical assessability on the artificial bone model. METHODS: An artificial bone model was instrumented with pedicle screws in the thoracic and lumbar spine region (Th10 to L5). Then, the acquisition trajectory of the CBCT (Cios Spin, Siemens, Germany) to the pedicle screws was systematically changed in 5° steps in angulation (- 30° to + 30°) and swivel (- 30° to + 30°). Subsequently, radiological evaluation was performed by three blinded, qualified raters on image quality using 9 questions (including anatomical structures, implant position, appearance of artifacts) with a score (1-5 points). For statistical evaluation, the image quality of the different acquisition trajectories was compared to the standard acquisition trajectory and checked for significant differences. RESULTS: The angulated acquisition trajectory increased the score for subjective image quality (p < 0.001) as well as the clinical assessability of pedicle screw position (p < 0.001) highly significant with particularly strong effects on subjective image quality in the vertebral pedicle region (d = 1.06). Swivel of the acquisition trajectory significantly improved all queried domains of subjective image quality (p < 0.001) as well as clinical assessability of pedicle screw position (p < 0.001). The data show that maximizing the angulation or swivel angle toward 30° provides the best tested subjective image quality. Angulation and swivel of the acquisition trajectory result in a clinically relevant improvement in image quality in intraoperative 3D imaging (CBCT) during dorsal instrumentation of the spine.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Tomografia Computadorizada de Feixe Cônico Espiral , Cirurgia Assistida por Computador , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Tomografia Computadorizada de Feixe Cônico , Imageamento Tridimensional/métodos , Cirurgia Assistida por Computador/métodos
4.
J Orthop Surg Res ; 18(1): 159, 2023 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-36864448

RESUMO

INTRODUCTION: Posttraumatic swelling causes a delay in surgery, a prolonged hospital stay and a higher risk of complications. Thus, soft tissue conditioning following complex ankle fractures is of central importance in their perioperative management. Since the clinical benefit of VIT usage on the clinical course has been shown, it should now be investigated whether it is also cost-efficient in doing so. MATERIALS AND METHODS: Included are published clinical results of the prospective, randomised, controlled, monocentric VIT study that have proven the therapeutic benefit in complex ankle fractures. Participants were allocated in a 1:1 ratio into the intervention group (VIT) and the control group (elevation). In this study, the required economic parameters of these clinical cases were collected on the data of the financial accounting and an estimation of annual cases had been performed to extrapolate the cost-efficiency of this therapy. The primary endpoint was the mean savings (in €). RESULTS: Thirty-nine cases were studied in the period from 2016 to 2018. There was no difference in the generated revenue. However, due to lower incurred costs in the intervention group, there were potential savings of about €2000 (pITT = 0.073) to 3000 (pAT = 0.008) per patient compared to the control group with therapy costs decreasing as the number of patients treated increases from €1400 in one case to below €200 per patient in 10 cases. There were 20% more revision surgeries in the control group or 50 min more OR time, respectively, and an increased attendance by staff and medical personnel of more than 7 h. CONCLUSIONS: VIT therapy has been shown to be a beneficial therapeutic modality, but it is so not only in regard to soft-tissue conditioning but also cost efficiency.


Assuntos
Fraturas do Tornozelo , Humanos , Fraturas do Tornozelo/cirurgia , Estudos Prospectivos , Pessoal de Saúde , Tempo de Internação , Tecnologia
5.
Sci Rep ; 13(1): 661, 2023 01 12.
Artigo em Inglês | MEDLINE | ID: mdl-36635339

RESUMO

Soft-tissue conditioning due to posttraumatic oedema after complicated joint fractures is a central therapeutic aspect both pre- and postoperatively. On average, 6-10 days pass until the patient is suitable for surgery. This study compares the decongestant effect of vascular impulse technology (VIT) with that of conventional elevation. In this monocentric RCT, 68 patients with joint fractures of the upper (n = 36) and lower (n = 32) extremity were included and randomized after consent in a 1:1 ratio. Variables were evaluated for all fractures together and additionally subdivided into upper or lower extremity for better clinical comparability. Primary endpoint was the time in days from hospital admission to operability. Secondary endpoints were total length of stay, oedema reduction, pain intensity, complications, and revisions. The time from admission until operability was reduced by 1.4 (95% CI - 0.4; 3.1) days in the mITT analysis (p = 0.120) and was statistically significant with 1.7 (95% CI 0.1; 3.3) days in the as-treated sensitivity analysis (pAT = 0.038). Significantly less pain and a faster oedema reduction were found in the intervention group. Due to rare occurrences, nothing can be concluded regarding complications and revisions. Administration of VIT therapy did not lead to a significant reduction in time until operability in the whole population but was superior to elevation for soft-tissue conditioning and pain reduction. However, there was a significant reduction by 2.5 days (95% CI 0.7; 4.3) in the subgroup of lower extremity fractures. VIT therapy therefore seems to be a helpful tool in the treatment of posttraumatic oedema after complex joint fractures of the lower and upper extremity, especially in tibial head and lower leg fractures.


Assuntos
Fraturas Ósseas , Humanos , Edema/etiologia , Fraturas Ósseas/complicações , Fraturas Ósseas/cirurgia , Articulações , Extremidade Inferior , Fatores de Tempo , Resultado do Tratamento
6.
Eur J Trauma Emerg Surg ; 49(1): 373-381, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36048181

RESUMO

PURPOSE: Intraoperative 3D imaging has become a valued tool in assessing the quality of reduction and implant placement in orthopedic trauma surgery. In our institution, 3D imaging is used routinely since 2001. To evaluate the intraoperative findings and consequences of this technique, intraoperative revision rates in cases with 3D imaging were analyzed. METHODS: All operative procedures carried out with intraoperative 3D imaging between August 2001 and December 2016 were included. The scans were assessed intraoperatively and documented thereafter. In case of malreduction or misplaced implants, an immediate revision was performed. The number of scans per case as well as the findings and consequences drawn regarding the anatomical region were analyzed. RESULTS: 4721 cases with 7201 3D scans were included in this study. The most common anatomical regions were the ankle (22.3%), the calcaneus (14.8%) and the tibial head (9.5%). In 19.1% of all cases, an intraoperative revision was performed. The highest revision rates were found with 36.0% in calcaneal fractures, 24.8% in fractures of the tibial plateau, 22.3% in injuries of the ankle. In 52.0% of revisions, the reduction was improved regarding intra-articular steps or joint congruency. In 30.5% an implant was corrected. CONCLUSION: Intraoperative revision due to results of 3D imaging was performed in almost one-fifth of cases. This illustrates the improved possibilities to detect malreduction and implant misplacements intraoperatively and thus the abilities to improve surgical outcome. LEVEL OF EVIDENCE: III.


Assuntos
Fraturas Ósseas , Imageamento Tridimensional , Humanos , Imageamento Tridimensional/métodos , Fixação Interna de Fraturas/métodos , Estudos Retrospectivos , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Reoperação
7.
J Imaging ; 8(4)2022 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-35448235

RESUMO

Intricate lesions of the musculoskeletal system require reconstructive orthopedic surgery to restore the correct biomechanics. Careful pre-operative planning of the surgical steps on 2D image data is an essential tool to increase the precision and safety of these operations. However, the plan's effectiveness in the intra-operative workflow is challenged by unpredictable patient and device positioning and complex registration protocols. Here, we develop and analyze a multi-stage algorithm that combines deep learning-based anatomical feature detection and geometric post-processing to enable accurate pre- and intra-operative surgery planning on 2D X-ray images. The algorithm allows granular control over each element of the planning geometry, enabling real-time adjustments directly in the operating room (OR). In the method evaluation of three ligament reconstruction tasks effect on the knee joint, we found high spatial precision in drilling point localization (ε<2.9mm) and low angulation errors for k-wire instrumentation (ε<0.75∘) on 38 diagnostic radiographs. Comparable precision was demonstrated in 15 complex intra-operative trauma cases suffering from strong implant overlap and multi-anatomy exposure. Furthermore, we found that the diverse feature detection tasks can be efficiently solved with a multi-task network topology, improving precision over the single-task case. Our platform will help overcome the limitations of current clinical practice and foster surgical plan generation and adjustment directly in the OR, ultimately motivating the development of novel 2D planning guidelines.

8.
Orthop Traumatol Surg Res ; 108(7): 102922, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-33836282

RESUMO

BACKGROUND: Despite a substantial improvement in the operative treatment of tibial plateau fractures, the surgical procedure remains controversial and is generally challenging, as patients may develop postoperative arthritis and functional impairment of the knee joint. HYPOTHESIS: In the surgical treatment of tibial plateau fractures the intraoperative reposition quality has the greatest influence on the postoperative outcome, whereby misalignments of≥2mm lead to a worse result. PATIENTS AND METHODS: Forty-one patients with tibial plateau fractures were postoperatively examined. The operative treatment was performed under reduction control using an intraoperative 3D C-arm. The follow-up collective was divided into two groups depending on the intraoperative reduction result. The postoperative results were then evaluated using the following parameters: Lysholm score, Rasmussen score, Tegner score, SF-36 score, range of motion and pain level. RESULTS: Group 1 (articular surface incongruencies<2mm) tended to achieve a better result in all scores than group 2 (articular surface incongruencies≥2mm), in the Lysholm score (p=0.039), in the comparison of the range of motion (p=0.012) and the pain level (p=0.039) this was significant. Group 1 achieved an average of 90.71 points (group 2: 78.74) in the Lysholm score. The average range of motion of the knee joint was 138.93° in group 1 (group 2: 127.78°). The average value of the current pain level in group 1 was 1.14 (group 2: 2.63). DISCUSSION: Both study groups achieved a very good result compared to the available literature. It appears that reduction quality - which can be analyzed with intraoperative 3D imaging - plays the most important role in postoperative quality of life and functional outcome. Intraoperative adjustments of the reduction should therefore be performed on joint surface irregularities with a size above 2mm. LEVEL OF EVIDENCE: III; retrospective case control study.


Assuntos
Qualidade de Vida , Fraturas da Tíbia , Humanos , Estudos Retrospectivos , Fixação Interna de Fraturas/métodos , Estudos de Casos e Controles , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Fraturas da Tíbia/etiologia , Dor/etiologia , Resultado do Tratamento
9.
Eur J Trauma Emerg Surg ; 48(2): 1445-1452, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34137911

RESUMO

PURPOSE: The aim of the cadaveric study was to determine the effects of an unstable ankle fracture on the position of the fibula in the incisural notch and subsequently to evaluate the alterations resulting from the individual steps of a guideline-based osteosynthesis. METHODS: In a specimen model with 20 uninjured fresh-frozen lower legs with induced unstable fracture of the fibula (type Weber C), a guideline-based osteosynthesis was performed. The distances between the anterior and posterior edges of the tibia and fibula and in the center of the incisural notch, as well as the rotation angle of the fibula, were measured in the acquired 3D image data sets and were compared with the intact condition of the ankle mortise. RESULTS: The dissection of the syndesmosis and osteotomy of the fibula results in an external rotation the fibula by 3.6° (p = 0.000), while the distance between the anterior edge of the tibia and the fibula widens by 1.86 mm (p = 0.000). After osteosynthesis of the fibula and transfixation of the syndesmotic region using a positioning screw, the posterior distance is no longer substantially increased by 0.22 mm (p = 0.103) but also reduced by 0.1 mm (p = 0.104) in the tibiofibular notch. The external rotation of the fibula remains slightly increased by just 0.45° (p = 0.009). CONCLUSION: The results indicate that there is a tendency for over-compression when adjusting the tibiofibular distance and that the fibula in the tibiofibular notch tends to remain slightly rotated externally.


Assuntos
Fraturas do Tornozelo , Traumatismos do Tornozelo , Tornozelo , Fraturas do Tornozelo/cirurgia , Traumatismos do Tornozelo/cirurgia , Articulação do Tornozelo/cirurgia , Cadáver , Fíbula/cirurgia , Humanos , Tíbia/cirurgia
10.
Bone Joint J ; 103-B(4): 746-754, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33789481

RESUMO

AIMS: Complex joint fractures of the lower extremity are often accompanied by soft-tissue swelling and are associated with prolonged hospitalization and soft-tissue complications. The aim of the study was to evaluate the effect of vascular impulse technology (VIT) on soft-tissue conditioning in comparison with conventional elevation. METHODS: A total of 100 patients were included in this prospective, randomized, controlled monocentre study allocated to the three subgroups of dislocated ankle fracture (n = 40), pilon fracture (n = 20), and intra-articular calcaneal fracture (n = 40). Patients were randomized to the two study groups in a 1:1 ratio. The effectiveness of VIT (intervention) compared with elevation (control) was analyzed separately for the whole study population and for the three subgroups. The primary endpoint was the time from admission until operability (in days). RESULTS: The mean length of time until operability was 8.2 days (SD 3.0) in the intervention group and 10.2 days (SD 3.7) in the control group across all three fractures groups combined (p = 0.004). An analysis of the subgroups revealed that a significant reduction in the time to operability was achieved in two of the three: with 8.6 days (SD 2.2) versus 10.6 days (SD 3.6) in ankle fractures (p = 0.043), 9.8 days (SD 4.1) versus 12.5 days (SD 5.1) in pilon fractures (p = 0.205), and 7.0 days (SD 2.6) versus 8.4 days (SD 1.5) in calcaneal fractures (p = 0.043). A lower length of stay (p = 0.007), a reduction in pain (ppreop = 0.05; pdischarge < 0.001) and need for narcotics (ppreop = 0.064; ppostop = 0.072), an increased reduction in swelling (p < 0.001), and a lower revision rate (p = 0.044) could also be seen, and a trend towards fewer complications (p = 0.216) became apparent. CONCLUSION: Compared with elevation, VIT results in a significant reduction in the time to achieve operability in complex joint fractures of the lower limb. Cite this article: Bone Joint J 2021;103-B(4):746-754.


Assuntos
Fraturas do Tornozelo/complicações , Edema/etiologia , Edema/prevenção & controle , Dispositivos de Compressão Pneumática Intermitente , Feminino , Alemanha , Humanos , Escala de Gravidade do Ferimento , Extremidade Inferior/irrigação sanguínea , Masculino , Pessoa de Meia-Idade , Medição da Dor , Estudos Prospectivos
11.
Injury ; 52(10): 2730-2737, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32113742

RESUMO

BACKGROUND: Intraoperative imaging is regularly used for intraoperative reduction control and evaluation of the implant position in trauma surgery. 2D imaging is limited, especially in complex anatomical regions such as the pelvis. The introduction of mobile 3D C-arms (CBCT: cone-beam computed tomography) has significantly improved intraoperative assessment. Nevertheless, there are still limitations regarding the field of view and metal artifacts. The purpose of this study was to evaluate the potential of intraoperative computed tomography (iCT) in surgical treatment of sacroiliac (SI) injuries. METHODS: Twenty-five cases with injuries of the posterior pelvic ring involving the SI region that were surgically treated with navigated SI screws using the mobile iCT Airo (Brainlab, Munich, Germany) were analysed. Subsequently, the data were compared with historical control groups (CBCT with and without navigation; 2D fluoroscopy only). RESULTS: The average score for subjective image quality achieved using the Likert scale is significantly higher for the iCT (4.48 ± 0.65) than for the CBCT (3.04 ± 0.69) with p = 0.00. The average duration of surgery using iCT was 189.32 ± 88.64 min, which was not significantly different from the control groups (p = 0.14 - 0.70). The average fluoroscopy time using iCT was 81.96 ± 97.34 s, which was significantly shorter than in all of the control groups (p = 0.00 - 0.03). The rate for postoperatively detected complications after using iCT was 0% (n = 0). Compared with the 2D-only control group (25%; n = 1), there is a significant difference (p = 0.01). The remaining two control groups showed no significant differences (p = 0.09 - 0.19). CONCLUSIONS: The iCT provides excellent image quality that allows reliable assessment of fracture reduction and implant placement even in complex anatomical regions. The radiation exposure for the medical staff is reduced by decreasing the fluoroscopy time without significantly prolonging the surgical time. Overall, the possibility of intraoperative correction improves clinical outcome and patient treatment in the long term.


Assuntos
Imageamento Tridimensional , Cirurgia Assistida por Computador , Tomografia Computadorizada de Feixe Cônico , Fluoroscopia , Humanos , Tomografia Computadorizada por Raios X
12.
Eur J Trauma Emerg Surg ; 47(4): 897-903, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32100086

RESUMO

PURPOSE: Acute unstable syndesmotic lesions are regularly treated with closed or open reduction and fixation with either a positioning screw or tight rope. Conventional fluoroscopy is limited to identify a malreduction of the ankle mortise. The aim of the study was to validate the reduction criteria of intraoperative cone beam CT in unstable syndesmotic injuries by analyzing the clinical outcome. METHODS: Acute unstable syndesmotic injuries were treated with a positioning screw fixation, and the reduction in the ankle mortise was evaluated with intraoperative cone beam CT. The patients were grouped postoperatively according to the radiological reduction criteria in the intraoperative 3D images. The reduction criteria were unknown to the surgeons. Malreduction was assumed if one or more reduction criteria were not fulfilled. RESULTS: Seventy-three of the 127 patients could be included in the study (follow-up rate 57.5%). For 41 patients (56.2%), a radiological optimal reduction was achieved (Group 1), and in 32 patients (43.8%) a radiological adverse reduction was found (Group 2). Group 1 scored significantly higher in the Olerud/Molander score (92.44 ± 10.73 vs. 65.47 ± 28.77) (p = 0.003), revealed a significantly higher range of motion (ROM) (53.44 vs. 24.17°) (p = 0.001) and a significantly reduced Kellgren/Lawrence osteoarthritis score (1.24 vs. 1.79) (p = 0.029). The linear regression analysis revealed a correlation for the two groups with the values scored in the Olerud/Molander score (p < 0.01). CONCLUSION: The reduction criteria in intraoperative cone beam CT applied to unstable syndesmotic injuries could be validated. Patients with an anatomic reduced acute unstable syndesmotic injury according to the criteria have a significantly better clinical outcome.


Assuntos
Traumatismos do Tornozelo , Traumatismos do Tornozelo/diagnóstico por imagem , Traumatismos do Tornozelo/cirurgia , Articulação do Tornozelo/diagnóstico por imagem , Articulação do Tornozelo/cirurgia , Parafusos Ósseos , Tomografia Computadorizada de Feixe Cônico , Fixação Interna de Fraturas , Humanos , Resultado do Tratamento
13.
Eur J Trauma Emerg Surg ; 47(4): 891-896, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30963184

RESUMO

PURPOSE: The aim of the study is to identify an ideal location to measure fibular rotation in the ankle joint using axial computed tomography (CT) scans. Another objective was to detect the average fibular rotation in the uninjured ankle joint in a large cohort. METHODS: Standardised axial CT with coronal/sagittal reconstructions was performed in healthy ankle joints. Three investigators performed the measurements. In the axial view, each investigator appointed the ideal location to measure the angle of fibular rotation with the use of reference lines either 4, 6, 8 or 10 mm distal from the talar joint line. Inter- and intraobserver reliability, as well as the intraclass correlation coefficient, were determined. RESULTS: CT scans of one hundred individuals-78 males and 22 females-were analysed. The most common locations for measuring the fibular rotation were in 31% of cases 4 mm and in 51% of cases 6 mm distal the talar joint line. The external rotation of the fibula averaged 8.42° ± 4.86° (range 0°-26°). The intraclass coefficient correlations (ICC) for interrater and intrarater reliability were 0.75. CONCLUSIONS: The results of the study demonstrate a reproducible location to measure the fibular rotation in the ankle joint. The most convenient location to measure fibular rotation with a high reliability was 6 mm distal to the talar joint line.


Assuntos
Traumatismos do Tornozelo , Fíbula , Articulação do Tornozelo/diagnóstico por imagem , Feminino , Fíbula/diagnóstico por imagem , Humanos , Masculino , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X
14.
J Digit Imaging ; 33(5): 1136-1143, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32632648

RESUMO

The aim of our study was to evaluate whether software-based artifact reduction can achieve an improved image quality, using intraoperative 3D imaging in spinal surgery. A total of 49 intraoperative 3D image datasets of patients, who underwent surgery with pedicle screw placement, were retrospectively evaluated. The visibility of anatomical structures and the diameter of the pedicle screws were examined, with and without the application of the artifact reduction software. All software prototypes can improve the visibility of anatomical structures (P < 0.01), except MAR (metal artifact reduction) combined with IRIS (iterative reconstruction in image space) (P = 0.04). The algorithms MAR and MAR-2 can reduce the blooming artifacts significantly (P < 0.01), but SL (Shepp & Logan) cannot (P = 0.08-0.988). In summary, software-based artifact reduction for intraoperative 3D datasets can improve the current image quality. Additional information regarding the implant placement and the fracture reduction is therefore generated for the surgeon.


Assuntos
Artefatos , Imageamento Tridimensional , Algoritmos , Tomografia Computadorizada de Feixe Cônico , Humanos , Estudos Retrospectivos , Software
15.
In Vivo ; 34(3): 1555-1563, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32354962

RESUMO

BACKGROUND/AIM: In percutaneous radiotherapy dose-distribution and volumetric-load of normal tissue varies in different radiation-techniques. Haematotoxicity may lead to deficiencies of the immune and blood system or to secondary malignancies. Therefore, regular blood-counts are carried out during fractionated radiotherapy. The aim was to investigate patient haemogram courses during radiotherapy of localised prostate-cancer treated with different radiation-techniques (n=3). PATIENTS AND METHODS: In this prospective study, blood count changes were examined during fractionated radiotherapy (3D-conformal-RT/step-and-shoot-IMRT/helical-IMRT) on the prostate-region in localised prostate-cancer cases (n=50). RESULTS: The whole patient group displayed a small but significant reduction in leukocytes. This reduction was higher in the two IMRT groups compared to the 3D-group but without any case of leukopenia. Haemoglobin- or thrombocyte-levels did not significantly change. CONCLUSION: Regardless of the delivery mode used, localised fractionated irradiation of prostate region did not cause any clinically relevant haemogram changes in this study. These findings question the necessity of regular blood counts during fractionated radiotherapy of the prostate region for patients without any risk factors.


Assuntos
Neoplasias da Próstata/patologia , Neoplasias da Próstata/radioterapia , Idoso , Idoso de 80 Anos ou mais , Contagem de Células Sanguíneas , Relação Dose-Resposta à Radiação , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias da Próstata/sangue , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia Conformacional/efeitos adversos , Radioterapia Conformacional/métodos , Radioterapia de Intensidade Modulada/efeitos adversos , Radioterapia de Intensidade Modulada/métodos , Resultado do Tratamento
16.
J Orthop Surg Res ; 15(1): 115, 2020 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-32293501

RESUMO

BACKGROUND: Currently available procedures for the treatment of minimally displaced acetabular fractures include conservative treatment and minimally invasive percutaneous screw fixation. Screw fixation of acetabular fractures allows patients' early full-weight bearing due to improved biomechanic stability. Can the range of motion, pain and mobility and quality of life in patients with acetabular fractures be improved by minimally invasive screw fixation, compared to conservative treatment in the long term? METHODS: Patients treated for a minimally displaced acetabular fracture, either conservatively or by closed reduction percutaneous screw fixation, in the period from 2001 to 2013 were included in this retrospective study. Minimal displacement was considered to be less than 5 mm. As well as the collection and analysis of baseline data, Harris Hip Score, Merle d'Aubigné score and Short Form 12 (SF-12) questionnaire data were recorded in the context of a clinical study. To better account for confounding factors, patients of each group were matched. The matched-pair criteria included age, BMI, Letournel fracture classification and the presence of associated injuries. RESULTS: Twenty-five patients from each group were matched. On the Harris Hip Score, conservatively treated patients obtained 96 points (52-100, SD 17) vs. 89 points (45-100, SD 17, p = 0.624). On the Merle d'Aubigné score, conservatively treated patients obtained 17 points (10-18, SD 2) vs. 17 points (11-18, SD 2, p = 0.342). Patients with acetabular fractures treated by minimally invasive screw fixation did not result in improved quality of life, measured by SF-12 questionnaire, compared to conservatively treated patients (PCS 47, SD 9 vs. 44, SD 10; p = 0.294 and MCS 51, SD 7 vs. 53, SD 7; p = 0.795). CONCLUSIONS: The clinical results of the two groups revealed no statistically significant differences. From the data, it cannot be deduced that minimally invasive surgical therapy is superior to conservative treatment of minimally displaced acetabular fractures. Prospective randomised studies are recommended to allow reliable evaluation of both treatment options. TRIAL REGISTRATION: Retrospectively registered.


Assuntos
Acetábulo/lesões , Tratamento Conservador/tendências , Fraturas Ósseas/terapia , Procedimentos Cirúrgicos Minimamente Invasivos/tendências , Medição da Dor/tendências , Qualidade de Vida , Acetábulo/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Fixação Interna de Fraturas/tendências , Fraturas Ósseas/diagnóstico , Fraturas Ósseas/fisiopatologia , Humanos , Masculino , Análise por Pareamento , Pessoa de Meia-Idade , Limitação da Mobilidade , Amplitude de Movimento Articular/fisiologia , Estudos Retrospectivos , Resultado do Tratamento
17.
BMC Musculoskelet Disord ; 20(1): 534, 2019 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-31722696

RESUMO

BACKGROUND: The aim of the study was to evaluate the impact of reduction quality, using intraoperative 3D imaging, on quality of life and functional outcome in the operative treatment of tibial plafond fractures. METHODS: A group of patients with tibial plafond fractures was re-examined. The operative treatment was performed between September 2001 and October 2011. The follow-up examination was at least 2 years after the final surgical procedure. Final reduction result was assessed intraoperatively using a mobile 3D C-arm. A categorization with regard to descriptive parameters as well as type and size of joint surface irregularities was performed. Follow-up results were evaluated using: Olerud and Molander (O & M) score, Short-Form-36 (SF-36) score, movement deficit, Kellgren and Lawrence grade of osteoarthritis, and pain intensity. RESULTS: 34 patients with operatively treated tibial plafond fracture could be re-examined. Reduction quality had the greatest influence on functional result measured by the O & M score (p = 0.001) and the PCS domain of the SF-36 score (p = 0.018). Significant differences with regard to O & M score (p = 0.000), SF-36 score (p = 0.001 to p = 0.02; without MCS domain), movement deficit (p = 0.001), grade of osteoarthritis (p = 0.005) and pain (p = 0.001) could be verified under consideration of the reduction quality. The group with the anatomically more accurate reduction also showed a better result for clinical follow-up and quality of life. Furthermore, it is not the type of joint surface irregularity that is always decisive, but rather the size. CONCLUSIONS: Despite other relevant factors, it appears that reduction quality -which can be analyzed with intraoperative 3D imaging- plays the most important role in postoperative quality of life and functional outcome. Corrections should therefore be performed on joint surface irregularities with a size above 2 mm.


Assuntos
Fixação de Fratura , Consolidação da Fratura , Qualidade de Vida , Fraturas da Tíbia/cirurgia , Adulto , Tomografia Computadorizada de Feixe Cônico , Feminino , Fixação de Fratura/efeitos adversos , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/fisiopatologia , Fraturas da Tíbia/psicologia , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
18.
Sci Rep ; 9(1): 15445, 2019 10 28.
Artigo em Inglês | MEDLINE | ID: mdl-31659196

RESUMO

In order to achieve a clinically satisfying result and to prevent posttraumatic osteoarthritis in the treatment of unstable syndesmotic injuries, anatomically correct reduction is crucial. The objective of the study was to investigate three different reduction methods of the ankle mortise in unstable syndesmotic injuries. In a specimen model with 38 uninjured fresh-frozen lower legs, a complete syndesmotic dissection was performed. The ankle mortise was reduced with either a collinear reduction clamp, a conventional reduction forceps or manually with crossing K-wires. The reduction clamps and the K-wires were placed in a 0°-angle to the leg axis. The clamps were positioned on the posterolateral ridge of the fibula 20 mm proximal to the ankle joint line. A cone beam computed tomography was performed after dissection and after each reduction. Tibio-fibular distances and angles were determined. Despite significant differences in terms of overcompression (0.09-0.33 mm; p = 0.000-0.063) and the slight external rotation (0.29-0.47°; p = 0.014-0.07), the results show a satisfying reduction of the ankle mortise. There were no considerable differences between the reduction methods. It can therefore be concluded that the ankle mortise can be reduced with any of the methods used, but that the positioning and the contact pressure must be considered.


Assuntos
Fraturas do Tornozelo , Fixação Interna de Fraturas , Instabilidade Articular , Fraturas do Tornozelo/patologia , Fraturas do Tornozelo/cirurgia , Humanos , Instabilidade Articular/patologia , Instabilidade Articular/cirurgia , Masculino
19.
J Hand Surg Eur Vol ; 44(10): 1072-1078, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31475872

RESUMO

The aim of this study was to establish a radiographic method for detecting distal radioulnar joint instability intraoperatively. We created three successive instabilities in 12 intact Thiel-fixed upper limb specimens: lesion of the triangular fibrocartilage complex, Galeazzi injury and Essex-Lopresti injury. We made three-dimensional scans of the wrists in pronation and supination with a mobile C-arm. We used four validated measurement methods to quantify ulnar migration in the standard axial planes: the radioulnar line method, the subluxation ratio method, the epicentre method and the radioulnar ratio method. All types of instability showed significantly increased migration of the ulna compared with the control group. The subluxation ratio and the radioulnar ratio methods showed the highest sensitivity and specificity in detecting the instabilities. We conclude that these two methods are feasible for radiographically assessing distal radioulnar joint instability. Instability may be assumed if the migration of the ulna in the sigmoid notch is at least 45% of the length of the sigmoid notch, in which case wire transfixation of the distal radioulnar joint is advised.


Assuntos
Instabilidade Articular/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Articulação do Punho/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Cadáver , Humanos , Imageamento Tridimensional , Instabilidade Articular/fisiopatologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Fibrocartilagem Triangular/diagnóstico por imagem , Fibrocartilagem Triangular/lesões , Articulação do Punho/fisiopatologia
20.
Int J Comput Assist Radiol Surg ; 14(12): 2211-2220, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31392672

RESUMO

PURPOSE: Fracture reduction and fixation of syndesmotic injuries is a common procedure in trauma surgery. An intra-operative evaluation of the surgical outcome is challenging due to high inter-individual anatomical variation. A comparison to the contralateral uninjured ankle would be highly beneficial but would also incur additional radiation and time consumption. In this work, we pioneer automatic contralateral side comparison while avoiding an additional 3D scan. METHODS: We reconstruct an accurate 3D surface of the uninjured ankle joint from three low-dose 2D fluoroscopic projections. Through CNN complemented 3D shape model segmentation, we create a reference model of the injured ankle while addressing the issues of metal artifacts and initialization. Following 2D-3D multiple bone reconstruction, a final reference contour can be created and matched to the uninjured ankle for contralateral side comparison without any user interaction. RESULTS: The accuracy and robustness of individual workflow steps were assessed using 81 C-arm datasets, with 2D and 3D images available for injured and uninjured ankles. Furthermore, the entire workflow was tested on eleven clinical cases. These experiments showed an overall average Hausdorff distance of [Formula: see text] mm measured at clinical evaluation level. CONCLUSION: Reference contours of the contralateral side reconstructed from three projection images can assist surgeons in optimizing reduction results, reducing the duration of radiation exposure and potentially improving postoperative outcomes in the long term.


Assuntos
Traumatismos do Tornozelo/cirurgia , Articulação do Tornozelo/cirurgia , Fixação Interna de Fraturas/métodos , Imageamento Tridimensional/métodos , Monitorização Intraoperatória/métodos , Traumatismos do Tornozelo/diagnóstico por imagem , Articulação do Tornozelo/diagnóstico por imagem , Humanos , Modelos Anatômicos , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...